P28 Series

Lube Oil Pressure Cutout Control (With Time Delay)

Description

The P28 Series provides dependable shutdown on pressure of lubricated refrigeration compressors by sensing low lube oil pressure.  A built-in time delay switch, accurately compensated for ambient temperature, allows nuisance shutdowns on pressure drops of short duration during the running cycle.

Applications

  • semi-hermetic compressors
  • P28 Control measures pressure available to circulate oil through the lubrication system (Net oil pressure is the difference between oil gauge and crankcase pressure.)

Features

  • direct reading scale indication
  • adjustable setpoint
  • trip-free manual reset
  • replacement timing relays available
  • dust-protected switch

Accessories

  • all models listed on this page include a universal mounting bracket
  • replacement timing relays

Technical Specifications

The maximum bellows pressure is 180 psig (2241 kPa).

Electrical Ratings - Pilot Duty

Time Delay Heater Circuit Pilot Circuit Alarm Circuit (must be same voltage as pilot circuit) P28DA-1 Contact Rating 2 to 1: 2 to 3 (must be same voltage as time delay circuit)
Crankcase Heater: Term 2 to 1 Runlight: Term 2 to 3
120/240 VAC 750 VA, 120/240VAC 125VA, 120/240 VAC 10 amp 120VAC, 5 amp 240VAC 10W
24 VAC or VDC 125 VA, 24 VAC 57.5 VA, 24VDC 125 VA, 24 VAC 57.5 VA, 24VDC - 10W

Selection Chart

Code Number Time Delay Time Delay Heater Circuit VAC Type of Reset Range1 psig (kPa) Refrigerant (R) Pressure Connection
P28AA-1C2 90 sec 120/240 Manual 8 to 70

(55 to 483)

Non-Corrosive3 36 in. Cap with 1/4 in. Flare Nut
P28AA-2C4 60 sec 120/240 Manual 8 to 70

(55 to 483)

Non-Corrosive3 36 in. Cap with 1/4 in. Flare Nut
P28AA-17C5 120 sec 120/240 Manual 8 to 70

(55 to 483)

Non-Corrosive3 36 in. Cap with 1/4 in. Flare Nut
P28AA-18C 45sec 120/240 Manual 8 to 70

(55 to 483)

Non-Corrosive3 36 in. Cap with 1/4 in. Flare Nut
P28AN-1C 90 sec 120/240 Manual 8 to 70

(55 to 483)

Ammonia 1/4 in. Female NPT
P28DN-1C 90 sec with runlight and alarm terminals 120/240 Manual 8 to 70

(55 to 483)

Ammonia 1/4 in. Female NPT
P28DA-1C 90 sec with runlight and alarm terminals 120/240 Manual 8 to 70

(55 to 483)

Non-Corrosive3

 

36 in. Cap with 1/4 in. Flare Nut
P28GA-2C 90 sec 120/240 Automatic 8 to 70

(55 to 483)

Non-Corrosive3 36 in. Cap with 1/4 in. Flare Nut
P28NA-5C 120 sec 24 VAC or VDC Manual 8 to 70

(55 to 483)

Non-Corrosive3 36 in. Cap with 1/4 in. Flare Nut

1.     Switch differential approximately 5 psi (34 kPa).  Time delay relay energizes @ 9 psi (61 kPa) pressure difference, de-energized @ 14 psi (97kPa) difference.

2.    Replaces Ranco P30-3701

3.    Non-Corrosive refrigerants include R-12, R-22, R-134A, R-500, R-502 (r)

4.    Replaces Ranco P30-3601