P10 Series
Low Pressure Control (Single or 2-Stage)
Description
These pressure controls open or close electrical circuits
from a change in operating air pressure. R to Y terminals make (cut-in) on
pressure rise.
Applications
- pneumatic systems
- control of pumps or small air compressors
Features
- visible calibrated adjustable range scale
- snap-acting switch in a dust protected enclosure
- easily accessible wiring terminals
Accessories
- universal mounting bracket No. BKT16A-600R as
well as a barbed fitting supplied as standard
- model P10FC-4 has a jumper installed on the common
terminals
Technical Specifications
- model P10BJ-1 is rated for 24 amp non-inductive when
used as an SPST (R-Y). (See Electrical Ratings chart below).
- maximum allowable pressure is 150 psig (1034 KPa)
- maximum ambient temperature is 140°F (60°C)
Electrical Ratings
|
Motor Ratings VAC |
120 |
208 |
240 |
277 |
600 |
|
P10BC-7 |
|
AC Full Load Amp |
16.0 |
9.2 |
8.0 |
7.0 |
- |
|
AC Locked Rotor Amp |
96.0 |
55.2 |
48.0 |
42.0 |
- |
|
Non-Inductive Amp |
16.0 |
9.2 |
8.0 |
7.2 |
- |
|
Pilot Duty - 125VA at 24 to 277 VAC |
|
P10BG-3 |
|
AC Full Load Amp |
6.0 |
3.4 |
3.0 |
- |
- |
|
AC Locked Rotor Amp |
36.0 |
20.4 |
18.0 |
- |
- |
|
Non-Inductive Amp |
6.0 |
3.4 |
3.0 |
2.6 |
- |
|
Pilot Duty - 125VA at 24 to 277 VAC |
|
P10BJ-1 |
|
AC Full Load Amp |
18.0 |
9.2 |
8.0 |
7.0 |
- |
|
AC Locked Rotor Amp |
96.0 |
55.2 |
48.0 |
42.0 |
- |
|
Non-Inductive Amp |
Double Throw |
16.0 |
16.0 |
16.0 |
16.0 |
16.0 |
|
Single Throw |
24.0 |
24.0 |
24.0 |
24.0 |
24.0 |
|
Pilot Duty - 125VA at 24 to 600 VAC |
|
P10FC-4 |
|
AC Full Load Amp |
16.0 |
9.2 |
8.0 |
7.0 |
- |
|
AC Locked Rotor Amp |
96.0 |
55.2 |
48.0 |
42.0 |
- |
|
Non-Inductive Amp |
16.0 |
9.2 |
8.0 |
7.2 |
- |
|
Pilot Duty - 125VA at 24 to 277 VAC On 2- and 3-
stage models, maximum connected load shall not exceed 2000VA |
|
P10PA-11 |
|
AC Full Load Amp |
6.0 |
3.4 |
3.0 |
- |
- |
|
AC Locked Rotor Amp |
36.0 |
20.4 |
18.0 |
- |
- |
|
Non-Inductive Amp |
6.0 |
3.4 |
3.0 |
- |
- |
|
Pilot Duty - 125VA at 24 to 277 VAC On 2- and 3-
stage models, maximum connected load shall not exceed 2000VA |
Selection Chart
|
Code Number |
No. of Stages |
Contact Action |
Range psig (kPa) |
Factory Setting |
Pressure Connector |
|
psig (kPa) |
Switch Diff psi (kPa) |
|
P10BC-7C |
1 |
SPDT |
3 to 20 (21 to 138) |
12 (R to Y Cut-in) |
2 |
Barbed Fitting |
|
P10BG-3C |
1 |
SPDT |
2 to 20 (15 to 138) |
12 (R to Y Cut-in) |
0.2 |
1/8 in. Female NPSF |
|
P10BJ-1C |
1 |
SPDT |
3 to 20 (21 to 138) |
12 (R to Y Cut-in) |
2 |
1/8 in. Female NPSF |
|
P10FC-4C |
2 |
SPDT |
3 to 20 (21 to 138) |
(R-Y Cutout) Low
Stage 8 (55) |
(R-Y Cut in)
High Stage 12 (82) |
Low Stage 2 (14) |
High Stage 2 (14) |
1/8 in. Barbed Fitting |
|
P10PA-11C |
3 |
SPST |
3 to 20 (21 to 138) |
Stage 1 Open High 6
(41) |
Stages 2&3 Open High 18
(120) |
Stage 1
3 (21) |
Stages 2&3 0.4 (3) |
1/8 in. Barbed Fitting |
|